Tiempo de liberación:2019-03-26
Product Overview
Elemental Analyzer(EA) features one cross-belt type online detecting device for cement materials. It is mainly for online detection of element (compositions) contents during limestone batching, raw mix. EA is a modular structure and can be installed around a belt without the necessity to cut it. when EA operates, the belt slides through the internal supporting tank of the measuring unit and then
EA measures all the materials passing by. During the whole detection process, no material is contacted and there is no influence on belt operation.
when using EA, the measuring results are given once every minute, with the contents of each element and related quality control parameters being analyzed accurately. Effective control over the production process can be made according to the real-time detecting information from the analyzer to improve the production process, reduce the production cost and improve the product quality.
Operating Principle
EA adopts prompt gamma neutron activation analysis (PGNAA) technology. A fast neutron with an average energy of 2.35MeV is released from a neutron source. The fast neutron is moderated into thermal neutron by the measuring device, and the thermal neutron irradiates the material and occurs thermal neutron capture reaction with all elements in the material, emitting different gamma rays with different energy and intensity. By testing the energy in characteristic gamma rays, the element categories in the materials can be
distinguished, and by tesing the intensity of gamma rays with specific energy, the content of elements can be got.
When the detector receives gamma rays, pulsed light will occur, which will generate electric pulse after entering into the photoelectric multiplier. The electric pulse is magnified by electronic signal processing parts and converted through ADC, and then recombined gamma ray energy spectrum is generated. Afterwards, the element (components) of such energy spectrum cna be disclosed by microprocessor and advanced analysis software.
Product Composition
EA consists of such five parts as measuring unit, neutron source,detector, signal processing cabinet and host computer.
1.Measuring unit
Measuring unit is of modular frame structure, including key parts supporting the prompt gamma neutron activation (PGNA) reaction
during the measuring process. At the same time, it forms radiation protection against rays, so that the surrounding radiation dose meets the safety standards in GSR Part 3 which stipulated by IAEA, ensures the health and safety of working personnel.
2. Neutron source
Adopt 252Cf neutron source as excitation source. Radioactive material is totally sealed within double layers SS enclosure. The
source is put into the sealed source housing from sideway and is locked outside to keep it safe. The half-time of 252Cf is 2.6 years. After the half-life, new neutron source core should be supplemented to reach initial source intensity.
3.Detector
Detector is used to receive characteristic gamma rays emmited from materials and turned it into eletric signal. The signal is transmitted to signal processing cabinet through cable.
4.Signal processing cabinet
Signal processing cabinet adopts SS leak-proof structure to protect in -house facilities, it is dust-proof, moisture-proof and water-proof.
The signal processing cabinet contains peripheral equipment and detector signal receiving equipment that ensure the stable operation of the detector. And then the received analog signals is converted into digital signals and uploads them to the host.
Cable is used to connect signal processing cabinet and detector, optical fiber is used to connect signal processing cabinet and
host computer
5.Host computer
Host computer consists of hardware and software, mainly acquires and analyzes digital signals from signal processing cabinet,
calculates the contents of element and related qulity control parameters, so as to direct and control cement production.
The hardware is a computer and the computer is equipped with data trnamission interfaces. One interface exchanges data with
the factory control system vio OPC communication, and the other interface provides remote technical services via the Internet
(provided by the factory).
By using optimized analysis algorithm, the software can analyze complicated gamma energy spectrum, it presents the measuring
results once every minute, real-time dispaly and provide multiple ways to query historical data.
Performance Parameters
Applicative conveyor(mm) |
650 |
800 |
1000 |
1200 |
1400 |
1600 |
Analyzer length(mm)* |
2200 |
2200 |
2200 |
2200 |
2200 |
2200 |
Analyzer width(mm)* |
1700 |
1700 |
1700 |
2250 |
2250 |
2450 |
Analyzer height(mm)* |
1500 |
1500 |
1500 |
1700 |
1700 |
1700 |
Weight(kg)* |
2600 |
2600 |
2600 |
2900 |
3000 |
3300 |
Angle of support groove |
25°~45° |
|||||
Neutron source |
15~60μg Cf-252 |
|||||
Signal processing cabinet |
Protection class: IP66 Dimension: 1100×770×300mm |
|||||
Working temperature |
-30℃~50℃ |
|||||
Power supply |
~230V±10%, 50Hz/60Hz, 6.5A, 3-wire (L、N、PE) |
|||||
Measuring principle |
Prompt gamma neutron activation analysis (PGNAA) technology |
|||||
Analysis time |
The shortest time is 1 minute, settable by user |
|||||
Analysis element |
Si, Al, Fe, Ca, Mg, K, Na, S, Cl, Mn, P, Zn, N, etc. |
|||||
Calculate quality parameters |
LSF, KH, SM, IM, C3S, C2S, C3A, C4AF, Alkalinity and etc. |
*Size and Weight should be determined according to the application site
Product Characteristic
Comprehensiveness:Measuring all the materials passing by, with strong representativeness;
Fastness:Giving composition data once per minute;
Effectiveness:Providing key parameter data for production, so as to make effective control;